Sulfuric acid electromagnetic flowmeter installation location

2024-07-25

All of the electromagnetic flowmeter in the installation are certain requirements, Supmea electromagnetic flowmeter manufacturers talk to you about the choice of the installation location of the electromagnetic flowmeter for sulfuric acid.


  1. Try to avoid ferromagnetic objects and equipment with strong electromagnetic fields (such as large motors, large transformers, etc.) to prevent the magnetic field from affecting the working magnetic field and flow signal of the sensor.

  2. It should be installed in a dry and ventilated place as much as possible, and should not be installed in a humid or water-prone place.

  3. Avoid exposure to sunlight and rain as much as possible, and avoid ambient temperatures above 60°C and relative humidity above 95%.

  4. Choose a place that is easy for maintenance and convenient for activities.

  5. The flow meter should be installed at the rear end of the water pump and never on the suction side; the valve should be installed on the downstream side of the flow.

  Supmea has been producing electromagnetic flowmeters for many years. If you encounter any problems in the selection, installation, use and maintenance of electromagnetic flowmeters, you can contact Supmea staff at any time and we will answer your questions.