DN100 metal tube float flowmeter installation instructions

2025-01-06

DN100 metal tube float flowmeter adopts all-metal structure, Modular concept design, its pressure loss is small, the range ratio is large (10:1), easy to install and maintain, can be used in complex, harsh environments.


  1. You should be cautious about the installation site and be sure to choose a suitable place. Avoid unfavorable occasions such as high temperature heat source and strong vibration;

  2. When installing, pay attention to the position of the sensor in the horizontal pipe. Do not ignore this point. Generally, it should be installed sideways;

  3. Another important point about the sensor during installation is that the layer of pipes needs to be insulated;

  4. Generally speaking, for correct installation of upstream and downstream, it is important to ensure that there are sufficient straight pipe sections.

  5. The flow meter must be installed vertically. The measured fluid passes through the flow meter from bottom to top. The inlet and outlet must have a straight pipe section 5 times the diameter of the instrument. For newly installed pipelines, the pipelines should be flushed before installing the flow meter.

  6. To facilitate the maintenance and replacement of the flow meter, a bypass pipeline must be connected when the meter is installed.

  7. A valve should be installed upstream of the flow meter, and a flow control valve should be installed downstream at a position 5 to 10 times the diameter of the meter. For small-diameter meters, a filter should be installed upstream. If the measured medium contains magnetic substances, a magnetic filter should be installed in front of the flow meter.

  8. When the measured medium is dirty, the tube and float should be cleaned in time.

  9. The measurement accuracy of metal rotor flowmeter is generally 215 level. When higher measurement accuracy is required, metal rotor flowmeter should not be selected.