E+H electromagnetic flowmeter working principle

2024-11-18

The working principle of E+H electromagnetic flowmeter. German E+H flowmeter and Endress+Hauser electromagnetic flowmeter are our main products.


The working principle of E+H electromagnetic flowmeter. German E+H flowmeter and Endress+Hauser electromagnetic flowmeter are our main products. We get the goods directly from the E+H factory in Germany without going through domestic agents and distributors. You can get low discounts directly, enjoy fast delivery, and fly directly back to Shanghai once a week. Liquid, gas and steam flow measurement Product overview for liquid, gas and steam measurement ensuring consistent product quality, safety, process optimization and environmental protection – these are just some of the reasons why flow measurement is increasingly important. Measuring water, natural gas, steam, mineral oil, and chemicals is a daily routine in certain industries. No one measurement technology fits every industry, so you can choose the right flow meter to meet your process needs from our comprehensive product range.

The advantages of E+H electromagnetic flowmeters range from communicable single measuring points to complete control system solutions: Our products tailored for your measurement process are your reliable choice. In recent years, with the development of process control automation and professional communication interfaces (bus systems), flow measurement has entered more and more new application fields. A variety of measurement principles are available for you to choose from - electromagnetic principle for volume flow measurement, mass flow measurement based on the Coriolis force principle or the thermal measurement principle, volume flow measurement based on the vortex or ultrasonic principle. Promag P sensors are used in chemical and process applications. Measurement of high temperature and corrosive media. Used in conjunction with the integrated transmitter, Promag P 300 offers flexible operation and easy system integration: wiring on the same side of the instrument, remote display, improved connection methods. Heartbeat Technology ensures compliance and process safety at all times. Advantages of E+H electromagnetic flowmeter Wide range of applications: A variety of welding parts materials are available Energy-saving flow measurement: No throttling parts, ensuring no pressure loss Maintenance-free: No moving parts Complete view of process information and diagnostic information: Provides a variety of users Custom input/output combinations and fieldbuses reduce complexity and diversity: user-defined input/output functions come with verification functions: built-in Heartbeat Technology E+H electromagnetic flowmeter liquid measurement principle electromagnetic switch product title The flowmeter has a high medium temperature and is compact and convenient for transmitters. For chemical and process applications with corrosive liquids and high media temperatures.

Sensor Features Universal Application - A wide variety of wet materials. Energy-saving flow measurement – ​​no pressure loss due to cross-sectional shrinkage. Maintenance free - no moving parts. Nominal diameter: Max. D.N. All common approvals. The transmitter features complete access to processing and diagnostic information, numerous, freely combineable I/Os and integration. Reduced complexity and diversity - freely configurable I/O functions. Integrated verification-heartbeat technology. Compact dual chamber construction with 3 more I/Os. Comes with touch controls and WLABacklit display for N access. Nominal diameter range dn 15 - 600 (½24”) Wetted parts material Gasket: PFA; PTFE electrode: 1. l); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium; Double 1.4462 (not Success) S31803 base material measures variable volume flow, conductivity, and mass flow. Large measurement error. Volume flow (standard): o.r±0.5%. Volume flow (optional): o.r±0.2%. ±2 mm/s/s (0.08) Measuring range 4 dm³/min to 9600 m³/h (1 gal/min to 44 000 gal/min) Maximum process pressure PN 40, Class 300, 20 K Medium temperature range Lining material PFA:- 20 + 150°C (4 + 302°F) Bushing Material PFA High Temperature: -20 + 180°C (4 + 356°F) Lining PTFE Material: -40 + 130°C + 266°F (- 40) Ambient temperature range Carbon steel flange material: -10 + 60°C (+ 14 + 140°F) Stainless steel flange material: -40 + 60°C + 140°F (-40) Sensor housing material dn 15 - 300 (½12”): AlSi10Mg, coated DN 350 - 600 (14 - 24"): Carbon steel with protective varnish Transmitter housing material alsi10mg, coated; 1.4409 (CF3M) similar to 316L; high genetic transmitter design Stainless Steel Protection Rating Standard: IP66/67, Type 4 3 Outputs: 4 - 20 mA HART (Active/Passive) 4 - 20 mA WirelessHART 4 ​​- 20 mA (Active/Passive) Pulse/Frequency/Switch Output (Active/Passive) Dual Pulse Output (Active/Passive) E +H Magnetic Flowmeter Relay Output Input Status Input 4 - 20 mA Digital Communications Hart, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, Profinet, Ethernet/IP, OPC-UA Power Supply DC 24 VAC 100 to 230 VAC 100 to 230 V / DC 24 V (non-hazardous area) Hazardous area certification atex, IECEx cCSAus, INMETRO NEPSI, EAC product safety ce, C-tick EAC marking Functional safety according to IEC 61508 Functional safety, suitable for certification according to IEC 61511 Metrology certification and certificate calibration for safety-related applications (acc calibration facility. ISO/IEC 17025) Heartbeat technology complies with the traceability verification requirements of ISO 9001:2008 - Section 7.6a (tuv - attestation) pressure certification and certificate ped, CRN classification certificate 3.1 material hygiene type certification and certificate

Previous: Electromagnetic flowmeter selection and installation instructions Next: Electromagnetic flowmeter common faults and solutions

Related products

Please Fill In Your Request And We Will Contact You As Soon As Possible!