BURKERT 8045 Electromagnetic Flowmeter: Plug-in electromagnetic flowmeter for continuous flow measurement, with display, plug-in flow transmitter.
BURKERT 8045 Electromagnetic Flowmeter: Plug-in electromagnetic flowmeter for continuous flow measurement, with display, plug-in flow transmitter. Mainly used to measure and control liquid flow with conductivity greater than 20μs/cm. Contaminated and particle-containing liquids can be accurately measured.
Detailed introduction of BURKERT flowmeter
BURKERT 8045 electromagnetic flowmeter selection and detailed explanation
Plug-in electromagnetic flowmeter, used for continuous flow measurement, with display . Basic parameters
Medium temperature -10——+110 degrees Celsius
High ambient temperature -10——+60 degrees Celsius
Measuring range 0.1-10m/s
The measurement accuracy is less than 2% BURKERT flowmeter, BURKERT flowmeter
The repeatability is 0.25%
Waterproof level IP65
Power supply pressure 18-36VDC
Pipe diameter DN15-DN4000 (connectors need to be purchased separately)
Media: clean to pollution-free (non-magnetic ) Liquid, conductivity greater than 20μs/cm and viscosity less than 1000cST. Pulsation-free flow.
Measuring range: 0.1 to 10 m/s (1 to 50,000 liters/min)
Rated diameter: DN15 to DN400 (1/2" to 16")
Output signal: 4-20mA or NPN/PNP optional relay output
Connector material: stainless steel 316L, brass, PVC, PP, PVDF or PE
Connection interface: thread, flange, oil Ning, welding port, shaft saddle or welding head
(G, NPT, Rc, ASTM, JIS, DIN)
Pressure level: PN16 (metal) PN10 (plastic)
Temperature range: High +80 degrees (depending on the joint material)
BURKERT 8045 electromagnetic flowmeter selection and detailed explanation BURKERT electromagnetic flowmeter (all in one) ) type electromagnetic flowmeter consists of two parts: sensor and converter. It is based on Faraday's law of electromagnetic induction and is used to measure the volume flow of conductive liquids with a conductivity greater than 5 μS/cm. It is an inductive instrument that measures the volume flow of conductive media. In addition to measuring the volume flow of general conductive liquids, it can also be used to measure the volume flow of highly corrosive liquids such as strong acids and alkalis, and uniform liquid-solid two-phase suspension liquids such as mud, pulp, and paper pulp.
BURKERT 8045 electromagnetic flowmeter selection and detailed explanation is widely used in flow measurement in petroleum, chemical industry, metallurgy, textile, papermaking, environmental protection, food and other industrial sectors and municipal management, water conservancy construction, river dredging and other fields. Diesel, oilHigh-precision measurement of impurity-free oily liquids such as lubricating oil and heavy oil.
2. Product features of BURKERT 8045 electromagnetic flowmeter
1) Measurement is not affected by changes in fluid density, viscosity, temperature, pressure and conductivity.
2) There are no flow-blocking parts in the measuring pipe, no pressure loss, and low requirements for straight pipe sections. It has excellent adaptability to slurry measurement.
3) Reasonable selection of electrode and lining materials means they have good corrosion resistance and wear resistance.
4) Full digital quantity, strong anti-interference ability, reliable measurement, high precision, flow measurement range up to 150:1
5) Ultra-low EMI switching power supply, suitable for power supply The voltage variation range is large and the anti-EMI performance is good.
6) Using a 16-bit embedded microprocessor, it has fast computing speed, high accuracy, programmable frequency and low-frequency rectangular wave magnet, which improves the stability of flow measurement and has low power consumption.
7) Using SMD devices and surface mount (SMT) technology, the circuit has high reliability.
8) There are no moving parts and no flow-blocking parts in the pipeline, so there is almost no additional pressure loss during measurement.
9) The measuring range can be modified online according to the actual needs of the user on site.
10) The measurement results have nothing to do with flow velocity distribution, fluid pressure, temperature, density, viscosity and other physical parameters.
11) High-definition backlit LCD display, full Chinese menu operation, easy to use, simple to operate, easy to learn and understand.
Power supply: 18...36VDC
BURKERT 8045 electromagnetic flowmeter selection and detailed explanation
The following products of our company, Germany's Burkert, are all In stock:
BURKERT universal solenoid valve: Type 0121, Type 0124, Type 0290, Type 0330, Type 0340, Type 0406, Type 6013, Type 6213, Type 5281, Type 5404...
BURKERT analysis solenoid valve: 6013, 6011, 0127, 6606, 0124, 6124, 6126, 6021, 6022, 6023 type...BURKERT pneumatic valve: type 2000 angle seat valve, 2030 pneumatic diaphragm Valve, 2712 pneumatic control valve, 2731 pneumatic control valve...
BURKERT process control valve: 3230 pneumatic, 2652 ball valve, 2675 butterfly valve, 3232 manual diaphragm valve, 2702+1067 pneumatic control valve...
BURKERT flowmeter: 8030 flow sensor, 8035 flow controller with display, 8045 type electromagnetic flow meter, 8075 type volumetric flow meter…...BURKERT (Baode) flowmeter, Baode flowmeter
BURKERT pressure transmitter: type 8311, type 8314, type 8320, type 8323...
BURKERT explosion-proof Solenoid valve: type 6519, type 6518, type 5281, type 5282, type 6014, type 0780...
BURKERT stainless steel solenoid valve: type 0330, type 6213, type 290, type 5282, type 6014...
BURKERT conductivity transmitter: type 8225, type 8226...
BURKERT 8072 flow sensor: German BURKERT gear flow sensor type 8072, German BURKERT volumetric flow transmitter BURKERT flow Meter BURKERT sensor BURKERT flow sensor
BURKERT 8045 electromagnetic flowmeter selection and detailed explanation Model:
194943N 0450-H-060-GM81-FF-EXI/21
194944P 0450-H-060-GM81-FI-EXI/21194945Q 0450-L-060-GM81-FF-EXI/21
194966M H080-GM82-GM82 -B5-110/56-05
Hangzhou Economic Development Area,Hangzhou 310018,China