Range modification of an explosion-proof electromagnetic flowmeter usually involves adjusting its internal parameters or replacing key components to adapt to different flow measurement needs.
1. Introduction to electromagnetic flow measurement process
Electromagnetic flowmeter is an instrument that calculates flow rate by sensing the speed of liquid or gas flowing through a pipe. The flow measurement range depends on the coil parameters and chip performance of the electromagnetic flowmeter. However, in practical applications, different occasions require different flow measurement ranges. Therefore, the range of the electromagnetic flowmeter needs to be modified.
2. Steps to modify the electromagnetic flow measurement range
1. Adjust the coil parameters
The coil parameters of the electromagnetic flowmeter affect the measurement range one of the important factors. If you need to increase the measuring range of the electromagnetic flowmeter, you can increase the measuring range of the electromagnetic flowmeter by adjusting the parameters of the coil.
The specific steps are as follows:
(1) Find the coil parameter adjustment device of the electromagnetic flowmeter, which is generally located on the casing of the electromagnetic flowmeter.
(2) Use the adjustment device to gradually adjust the coil parameters of the electromagnetic flowmeter until the required range is reached.
2. Replace the electromagnetic flowmeter chip
If the coil of the electromagnetic flowmeter has reached the upper performance limit, the electromagnetic flowmeter chip needs to be replaced. The performance of the electromagnetic flowmeter chip determines the measuring range of the electromagnetic flowmeter. Different electromagnetic flowmeter chips have different measuring ranges.
The steps to replace the electromagnetic flowmeter chip are as follows:
(1) Open the casing of the electromagnetic flowmeter and find the electromagnetic flowmeter chip.
(2) Remove the original electromagnetic flowmeter chip and clean it.
(3) Install the new electromagnetic flowmeter chip, paying attention to the direction and fixation.
(4) Recalibrate and debug the electromagnetic flowmeter to ensure the normal performance of the new chip.
3. Precautions and solutions to common problems
1. Precautions
(1) When modifying the electromagnetic flow measurement range, the flow needs to be measured accurately value to ensure the accuracy of the electromagnetic flowmeter measurement results.
(2) When replacing the electromagnetic flowmeter chip, you need to select a suitable chip model and pay attention to the direction and fixation method of the chip.
(3) When modifying the electromagnetic flowmeter, attention needs to be paid to preventing magnetic field interference and electrostatic interference.
2. Solutions to common problems
(1) The electromagnetic flowmeter cannot work stably. This may be due to improperly adjusted coil parameters or incorrect chip installation. You can recheck whether the parameters and chip installation are correct.
(2) The measurement results of the electromagnetic flowmeter are inaccurate. This may be due to electromagnetic interference or other factors affecting the measurement results of the electromagnetic flowmeter. Interference sources can be checked or other electromagnetic flowmeters can be replaced at the measurement site.