IFM IFM Electromagnetic Flow Meter SM6000 hot sale in stock in Shanghai

2024-11-06

IFM IFM Electromagnetic Flow Meter SM6000 hot sale in stock in Shanghai


Case introduction

  IFM IFM Electromagnetic Flow Meter Model SM6000 Technical Specifications:

  Total number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1Measuring range0.1.... .25 l/min0.005.... .1.5 m³/hSystem interfaceThreaded connection G 1/2 DN15 Flat sealApplication-specific propertiesGold-plated contactsApplication adder function; for industrial applicationsInstallation via adaptersConnection of pipeworkMediumConductive liquids; water; water as a basic mediumMedium descriptionConductivity: ≥ 20 µS/cmViscosity: < 70 mm²/s (40 °C)Temperature of the medium [°C]-10...70Compressive strength [°C] -10...70 .70 Compressive strength [bar]16 Large value of permissible working pressure (for applications in accordance with CRN) [bar]17.7 Electrical data Operating voltage [V] 18..... .30 DC; (in accordance with EN50178 SELV/PELV) Current loss [mA]95; (24 V) Insulation resistance min. value [MΩ]100; (500 V DC) Protection class III Inverted phase protection available Power-on delay time [s]5 Total inputs/outputs Total number of inputs and outputs Digital outputs: 2; Analogue outputs: 1 Inputs Inputs Counter reset outputs Number of outputs 2 Output signals Switching signal; Analogue signal; Pulse signal; IO-Link; (configurable) Electrical design PNP/NPN Number of digital outputs 2 Output function Normally open/normally closed; (parameterisable) Voltage drop at switching output DC large [V]2 Continuous current load at switching output DC [mA]200 Number of analogue outputs 1 Analogue current output [mA]4..... .20; (adjustable range) load large value [Ω]500 Analogue voltage output [V]0..... .10; (adjustable range) load resistance small value [Ω]2000 Pulse output flowmeter short-circuit protection available Short-circuit protection type Pulse overload protection available Measuring/setting range Measuring range 0.1.... .25 l/min0.005.... .1.5 m³/hDisplay range-30... .30 l/min-1.8... .30 l/min-1.8... .1.8 m³/h Resolution0.02 l/min0.002 m³/hSwitching point, SP0.25.... .25 l/min0.015.... .1.5 m³/h recovery point, rP0.1...24.9 l/min0.015... .24.9 l/min0.005... .1.495 m³/h Measured value starting point, ASP0... .20 l/min0... .20 l/min0... .1.2 m³/h end point, AEP5... .25 l/min0.3... .25 l/min0.3... .1.5 m³/h in steps of 0.02 l/min0.002 m³/h Flow monitoring pulse value 0.00001.... .30 000 m³ Pulse length [s]0,01.... .2 Temperature monitoring Measuring range [°C] -20.... .80 Resolution [°C] 0.2 switching point, SP [°C] -19.2... .80 recovery point, rP [°C]-19.6..... .79.6 Measured value start point [°C]-20...60 Measured value end point [°C]-20... .60 Measured value end point [°C] 0...80 Setting steps [°C] -20...60 .80 Setting step [°C] 0.2 Accuracy/deviation Flow monitoring accuracy (in the measuring range) ± (0,8 % MW + 0,5 % MEW) Repeatability ± 0,2 % MEW Temperature monitoring accuracy [K] ± 2,5 (Q > 1 l/min) Reaction time Flow monitoring Reaction time [s] 0.15; (dAP = 0, T19) Programmable delay time dS, dr [s]0.... .50 Damping for switching outputs dAP [s]0.... .5 Response time for temperature monitoring T05 / T09 [s]T09 = 20 (Q > 1 l/min) Software/programming Parameter setting Flow rate monitoring; Quantity meter; Preset capacity meter; Temperature monitoring; Hysteresis/window; Normally open/normally closed; Output polarity; Current/voltage/pulse outputs; Start-up delay; Display can be switched off; Display unit Interfaces Communication interfaces IO-Link Transfer type COM2 (38,4 kBaud) IO-Link revision1.1SDCI standard IEC IO-Link Device ID569 / 00 02 39 h form factor Smart Sensor: Proces

Previous: Cold winter V cone flowmeter how to ‘keep warm’? Next: How to select electromagnetic flowmeter?

Related products

Please Fill In Your Request And We Will Contact You As Soon As Possible!

Whatsapp
Inquiry
Top