DN250 Electromagnetic flowmeter

DN250 Electromagnetic flowmeter

DN250 electromagnetic flowmeter is a high-precision, wide range ratio, small pressure loss, long life flow measurement equipment, widely used in a variety of conductive liquid flow measurement. In the installation and maintenance need to pay attention to some details to ensure its normal operation and measurement accuracy.


  • Highly accurate

    Electromagnetic flow meters have a high measurement accuracy, specially calibrated up to 0.2%.

  • Wide Range Ratio

    The ratio of the maximum flow rate to the minimum flow rate is generally 20:1 or more for a wide range of applications.

  • Low pressure loss

    There are no flow stoppers in the measuring pipe, so there are no additional pressure losses.

  • Long lifespan

    There are no moving parts in the measuring pipe and the sensor life is extremely long.

  • Corrosion resistance

    Different lining and electrode materials can be selected for different media to ensure the long-term stable operation of electromagnetic flowmeter.

  • Multifunctional

    The converter can simultaneously display volume flow percentage, actual flow rate and cumulative flow rate, and has a variety of communication interfaces and protocols to support.

 Product  Electromagnetic flow meter
 Model  SUP-LDG
 Diameter nominal  DN15~DN1000
 Nominal pressure  0.6~4.0MPa
 Accuracy  ±0.5%,±2mm/s(flowrate<1m/s)
 Liner material  PFA,F46,Neoprene,PTFE,FEP
 Electrode material  Stainless steel SUS316L, Hastelloy C, Titanium,
   Tantalum Platinum-iridium
 Medium temperature  Integral type: -10℃~80℃
   Split type: -25℃~180℃
 Ambient Temperature  -10℃~60℃
 Electrical conductivity  Water 20μS/cm other medium 5μS/cm
 Structure type  Tegral type, split type
 Ingress protection  IP65
 Product standard  JB/T 9248-1999 Electormagnetic Flowmeter

DN250 electromagnetic flowmeter is a device for flow measurement based on Faraday's law of electromagnetic induction. It utilizes the induced potential generated when the liquid flows in the magnetic field to measure the flow rate of the liquid and then calculate the flow rate. The device is widely used in industrial fields, such as waste water treatment, water supply, mud and corrosive liquid measurement.

Electromagnetic induction principle: when the conductive liquid in the magnetic field for the perpendicular direction of flow, will cut the magnetic induction line of force, thus in the pipeline on both sides of the electrodes to produce induced electric potential. The size of the induced potential is proportional to the flow rate of the liquid.

Signal conversion: The sensor transmits the induced potential as a flow signal to the converter. After a series of digital processing such as amplification, conversion, filtering, etc., the instantaneous flow rate and cumulative flow rate will be displayed on the LCD screen.

DN250 electromagnetic flowmeter is suitable for measuring various conductive liquids, such as domestic water, sewage, mud, lime and corrosive liquids. However, it should be noted that it can not measure the flow of gas, steam and pure water. At the same time, the temperature of the liquid also has certain requirements, generally not higher than 180 ℃.

Installation Notes:

Maintenance: